New HAWKMED HK-400III

New
24
Poland

Seller:

Poland

Product Details

HAWKMED
HK-400III
Syringe Pumps
17.05.2023
936

Product Description

New
Features and benefits of the pump:
Unique technology for intelligent recognition of syringes,
Large and colorful LCD display,
Different types of syringes: 5 ml, 10 ml, 20 ml, 30 ml, 50 ml,
The pump has an anti-bolus function,
Record history,
Adjustable buzzer volume,
Various visual and audible alarms,
The user has the option of defining syringe brands by himself,
Rotation of the handle by 90 ° easy mounting to the horizontal or vertical bar,
RS232 interface,
Antibolus function,
Technical data:
Supported syringes: Various brands of sterile syringes (5 ml, 10 ml, 20 ml, 30 ml, 50 ml / 60 ml),
The accuracy of the syringe: ± 2% (after correct calibration of the syringe),
Speed ​​of infusion:
5ml syringe: 0.1 ml - 150ml / h,
10ml syringe: 0.1 ml / h -300ml / h,
20ml syringe: 0.1 ml / h -600ml / h,
30ml syringe: 0.1 ml / h -900ml / h,
50ml syringe: 0.1 ml / h -1500ml / h,
Bolus indicator:
5ml syringe: 100-150 ml / h,
10 ml syringe: 100-300 ml / h,
20 ml syringe: 100-600 ml / h,
30 ml syringe: 100-900 ml / h,
50 ml syringe: 100-1500 ml / h,
Infusion volume: 0-9999.9 (ml),
Infusion volume: 0-9999.9 (ml)
Infusion rate KVO: 0.1-2ml / h, adjustable: default value: 0.1 ml / h,
Types of infusion modes: Rate mode, time mode, dosage mode, intermittent infusion mode, TIVA optional: drug library,
Alarms: end of infusion, near termination, empty, occlusion, discharged battery, disconnected syringe, no AC power supply, discharged battery, etc.,
Power supply: AC: 100 ~ 240V, 50 / 60Hz DC: 12V ± 1.2V,
Power consumption: 25VA,
Nurse call alert: optional,
Classification: Class I, type CF,
Dimensions: 230 × 137 × 139 mm (length × width × height),
Weight: ≤1.7kg,
Water tightness - IPX3 standard,
The pressure of the occlusion: 40-160 kPa,
Battery: Lithium-polymer battery, 7.4V, 1900mAh, Can operate for 6 hours when fully charged at 5 ml / h.,
Working conditions: Temperature: 5 ° ~ 40 °, relative humidity: 10 ~ 95%, atmospheric pressure: 86 ~ 106 kPa,
Transportation conditions: Temperature -20 ° ~ + 60 °, relative humidity: 10 ~ 95%, atmospheric pressure: 50 ~ 106 kPa,
Storage conditions: Temperature -20 ° ~ + 45 °, relative humidity: 10 ~ 95%, atmospheric pressure: 50 ~ 106 kPa,
Has a current Technical Passport issued, Warranty 24 months
Possibility of financing (only Poland): Instalments, Leasing, Loan

If you have any questions, please do not hesitate to contact us!
In case you don’t find the product you are interested in, please get in touch with us and we will do our best to find the perfect solution for YOU.

WE SPEAK ENGLISH

HABLAMOS ESPANOL

WIR SPRECHEN DEUTSCH

ON PARLE FRANCAIS

WIJ SPREKEN DUTCH

WE SPEAK RUSSIAN AND UKRAINIAN