New ABBOTT Endurity CORE

New
2023
Netherlands

Seller:

Netherlands

Product Details

ABBOTT
Endurity CORE
Pacemaker
17.05.2023
3346

Product Description

Product comes as a SET: Peelaway, Endurity PM and Tendril STS lead.

Product Highlights — Pacemaker

  • Allows patients to undergo 1.5 T or 3 T MRI scans when used with MRI Ready leads from Abbott.*

  • Physician-preferred size and physiologic shape minimize pocket size.

  • Outstanding longevity provides 14,4 years of service life,1 which is supported by a 10-year warranty.2

  • AutoCaptureTM pacing system offers the maximum in threshold adaptability and patient safety with ventricular Beat-by-BeatTM AutoCaptureTM pacing systems capture confirmation. The AutoCapture pacing system automatically delivers a 5,0 V backup safety pulse when noncapture is detected, and it may be programmed to either a bipolar or unipolar configuration.

    Ordering Information Contents: MRI Ready Pacing System

    PM1162 Endurity MRITM Pacemaker 41 × 50 × 6

    Indications: Implantation is indicated in one or more of the following permanent conditions: syncope, presyncope, fatigue, disorientation due to arrhythmia/bradycardia, or any combination of those symptoms. Rate-Modulated Pacing is indicated for patients with chronotropic incompetence, and for those who would benefit from increased stimulation rates concurrent with physical activity. Atrial Pacing is indicated for patients with sinus node dysfunction and normal AV and intraventricular conduction systems. Ventricular Pacing is indicated for patients with significant bradycardia and normal sinus rhythm with only rare episodes of A-V block or sinus arrest, chronic atrial fibrillation, severe physical disability.

    Contraindications: Single-chamber pulse generators are contraindicated in patients with an implanted cardioverter-defibrillator. Rate-Adaptive Pacing may be inappropriate for patients who experience angina or other symptoms of myocardial dysfunction at higher sensor-driven rates. An appropriate Maximum Sensor Rate should be selected based on assessment of the highest stimulation rate tolerated by the patient. Single- Chamber Ventricular Demand Pacing is relatively contraindicated in patients who have demonstrated pacemaker syndrome, have retrograde VA conduction, or suffer a drop in arterial blood pressure with the onset of ventricular pacing. Single-Chamber Atrial Pacing is relatively contraindicated in patients who have demonstrated compromise of AV conduction. For specific contraindications associated with individual modes, refer to the programmer’s on-screen help.

• A suite of state-of-the-art features — such as automaticity, ventricular AutoCaptureTM pacing system and SenseAbilityTM sensing algorithm technology — are designed to deliver optimal therapy for patients at implant and throughout their lives.

• Real-time electrogram (EGM) waveform, as well as the associated event markers that precede and follow a specific triggering event, can be programmed to automatically record up to 14 minutes of stored EGMs when encountering one or more programmable trigger options.

• Six-monthERI-EOLinterval.

• Anoptional,easy-to-usehandhelddevice (SJM MRI ActivatorTM device) can be used to program the device to preapproved MRI settings pre- and post- MRI scan, decreasing the number of workflow steps and increasing clinic efficiency.

*See MRI Conditional Parameters