UltiMate™ 3000 Fluorescence Detector
Develop highly selective methods for trace analytes or novel molecules with sensitivity three to six orders of magnitude greater than UV detection. The Thermo Scientific™ Dionex™ UltiMate™ 3000 Fluorescence Detectors offer four channel acquisition at up to 200Hz so you can optimize quantification on the most sensitive channel and single-channel detection at up to 100Hz. 2D or 3D synchro, excitation, emission scans, zero order mode, or multichannel acquisition offer flexibility for method development or routine sample characterization. A variable emission filter allows real-time, compound-related sensitivity optimization.
Recommended Use
The Thermo Scientific™ UltiMate 3000 Rapid Separation Fluorescence Detector FLD-3400 is recommended for method development labs that need flexibility in detecting novel compounds that don’t absorb in the UV-vis region of the spectrum. It is ideal for the analysis of carbohydrates, glycans, and polyaromatic hydrocarbons (PAHs) in combination with any Thermo Scientific™ Dionex™ UltiMate 3000 system. The ability to cleave and derivitize glycans from intact proteins or monoclonal antibodies eliminates interferences from coeluting matrix peptides.
Sensitive Fluorescence Performance
Data rates at up to 200Hz detect the narrowest peaks in UHPLC separations.
Maximum stray light suppression provides excellent sensitivity.
Low limits of detection are possible with a Raman S/N: >550 ASTM (>2100 using dark signal as noise reference).
Active flow cell temperature control ensures stable fluorophore activity independent of ambient temperature.
Long-life xenon flash lamp delivers the highest sensitivity and long-term operation.
Optional second photomultiplier (PMT) for Dual-PMT operation extends the wavelength range up to 900nm without sacrificing sensitivity in the standard wavelength range.
Easy-to-Use Fluorescence Detector
Large front panel display allows easy monitoring of detector status.
Flow cell syringe injection kit enables cost-effective off-line measurements.
Flow cell optimized for trace analysis with narrow-bore UHPLC and conventional HPLC columns.
Automate qualification monitoring and tracking of flow cells for regulatory compliance.
Thermo Scientific™ Dionex™ Chromeleon™ Chromatography Data System software offers performance optimization and instrument wellness monitoring for ease of use and maximum uptime.
Description
FLD-3100 Fluorescence Detector with Dual-PMT, one channel, without flow cell
Data Collection Rate
100 Hz
Detection Mode
Single Channel
Detector Type
High-Sensitivity Fluorescence
Type
Fluorescence Detector
Display
LCD Monitor
Filter
Fixed
Flow Cell Max. Pressure
290 psi
Flow Cell Thermostatting
15В°C Above Ambient -50В°C
Flow Cell Volume
8 ОњL
GLP Features
Automatic Instrument Qualification (AutoQ), System Wellness and Qualification Monitoring with Chromeleon Software, Lamp and Cell ID Chips.
Lamp
Xenon Flash Lamp
Lamp Pulse Frequency
300 Hz
No. of Channels
1
PC Connection
USB
Sensitivity
>550 ASTM
Spectral Bandwidth
20 nm
Temperature Control
Yes
Wavelength Accuracy
В±2 nm
Wavelength Range
200 to 880 nm
Weight (Metric)
18 kg
Unit Size
Each