Used Good SIEMENS DCA Vantage

Used Good
In stock
USA

Seller:

Product Details

SIEMENS
DCA Vantage
Hemoglobin analyzers
29.06.2023
472

Product Specifications

closed
1-40
Automatic
Whole blood, urine
3.88
Yes

Product Description

Siemens DCA Vantage Multi-Parameter POC HbA1c Analyzer
Includes:
-Fully functional Siemens DCA Vantage
-DCA Vantage Quick start up guide
-DCA Vantage operators guide
-DCA Unpacking guide
-DCA Quick Reference Guide
-DCA Version 3.2 Software Release Notes
-Power Cord
(Bar-Code scanner unit not included)
Features:
The DCA Vantage Analyzer is a multi-parameter, point-of-care analyzer for monitoring glycemic control in patients with diabetes and detecting early kidney disease.
Assays:
Hemoglobin A1c (HbA1c)

Albumin

Creatinine

Albumin-to-Creatinine (A:C) Ratio Results
Specifications:
Overview
System Description
Point-of-care immunoassay analyzer
Quantitative Tests
Hemoglobin A1c (whole blood): Range: 2.5% to 14% (4mmol/mol to 130 mmol/mol) Microalbumin/Creatinine (urine): Single test reports all three results for: Albumin: 5 to 300 mg/L; Creatinine: 15 to 500 mg/dL (1.3 to 44.2 mmol/L); Albumin-to Creatinine Ratio: 1 to 2000 mg/g (0.11 to 226 mg/mmol)
Test Format
Self-contained immunoassay cartridges
Test Measurement
Automatic, optional transmission
Test Method
HbA1c: monoclonal antibody agglutination reaction

Albumin: polyclonal goat anti-human albumin antiserum

Creatinine: Benedict Behre chemical reaction
Time to Test Results
HbA1c - 6 minutes
A:C Ratio - 7 minutes
Test Handling
Sample Volume
HbA1c - 1L whole blood

Microalbumin/Creatinine - 40L urine
Sample Preparation
No pretreatment; no pipetting required
Sample ID/Operator ID Entry
Optional; via touch screen or bar code reader
Calibration
Calibration
Lot-specific calibration card provides automatic calibration with every cartridge
Traceable to International Federation of Clinical Chemistry (IFCC) reference materials and test methods for measurement of HbA1c
Onboard Computer
Storage Capacity/Memory
4000 patient and/or control records

Up to 1,000 operator IDs
Display
Color touch screen with 1/4 VGA resolution
Data Export
Via USB flash drive to PC or direct to LIS/HIS or data manager, if interfaced
Quality Control/Compliance
Flexible QC Scheduling
None, Automatic Reminders or Required
QC Testing
Optional lockout if schedule not followed or QC fails
User/Operator Access
Restricted, if desired, to protect patient and QC data and prevent unauthorized use
Matching Lab Results/

Reference Method


Adjustable correlation to reference methods
Reference Ranges
User-definable reference ranges available for HbA1c
Computer/Peripheral Interfaces
Serial Port
RS232, ASTM
Ethernet Connection
ASTM or POCT1-A2
Bi-Directional Capabilities
ASTM: Remote computer can be set up to lock out patient tests

POCT1-A2: Remote computer can be set up to lock out patient tests, and send operator list to analyzer
USB-Port
Standard US.0
External Bar Code Reader (optional)
Serial (9 pin)
Onboard Printer
54 mm (2 in) width, thermal/label stock
External Printer
Supports standard PCL printer interface via USB port
General
Dimensions
9.0 (h) x 11.5 (w) x 10.5 (d) inches 25.4 (h) x 28.7 (w) x 27.7 (d) cm
Weight
3.88 kg (9.0 lb)
Power Requirements
100 to 240 VAC; 50/60 Hz
Line Leakage Current
<0.3 mA in normal condition

<0.5 mA in single fault condition
Maximum Power Input
70 VA; 30 watts
Ambient Operating Temperature
18C to 30C (64F to 86F) (Albumin)

15C to 32C (61F to 88F) (HbA1c)
Operating Temperature
5C to 40C (41F to 104F);

15% to 90% relative humidity
Safety
TUV SUD with CB Scheme, CSA-C22.2,

EN60601, IEC 60601, UL60601
EMC Emissions/Immunity
FCC 47: Part 15 (Class B),

EN60601-1-2 (Class B)
Refurbishment Protocol:
Our technicians decontaminate and clean equipment upon arrival at our facility and upon your purchase to create a neutral environment for your lab use.
Preliminary testing is then conducted on our equipment to identify potential defects. Upon completion, we replace all faulty and/or under-performing parts with original manufacturer parts that perform up to specification.
Any parts known to fail or malfunction on the piece of equipment are removed and replaced to insure the extended lifetime of your equipment.
Any necessary preventative maintenance is performed alongside repairs, so your purchase will be ready to go as soon as it arrives.
All of the electronics and boards are tested for proper function and response by our industry trained technicians. Any electronic deficiencies detected are immediately repaired.
Final testing cycles ensure your equipment performs fully at manufacturer specifications, guaranteeing you receive a properly working product ready for use.
Once we finish our rigorous testing and decontamination procedures, your order will be packaged to best protect it during shipment and may include delivery insurance depending on value.
* Free 30 day Returns
* Free Same Business Day Shipping
* Top Rated Plus Product
* This product is available also in different quantities and cases please ask us for details
- Call or email with your questions , Hablamos Espaol
- Ship from: IDE - Southern California. Global Shipping
- Details of item must be read carefully before buying and /or requesting return
Disclaimer: