New ADAPTICA 2WIN

New
12
In stock
USA

Seller:

Product Details

ADAPTICA
2WIN
Autorefractors
23.12.2023
939

Product Specifications

Hand

Product Description

2WIN Binocular Mobile Auto-Refractometer and Vision Analyzer

Reference ARADA-2 WIN

$6,995.00

12 months 0% Financing with pre-approved credit.

The smartest way to detect refractive errors and vision problems.

The 2WIN is a mobile binocular video refractometer and vision analyzer that measures both eyes at the same time, in real life vision conditions. It embodies the best and the most complete technologies to fully detect refractive errors, eye abnormalities and vision problems. It measures in the range of -15D to 15D for automatic measurement of dynamic pupils response to programmable light stimulations, and accurately center spectacle lenses. The 2WIN is capable of detecting Myopia, Hyperopia, Astigmatism, and other Amblyogenic factors. Additionally, it will provide evidence of sight anomalies that may be related to anisometrapia, anisocoria, strabismus, phorias

Technical Information

Target

  • Opticians & Optometrists – helps with practice efficiency
  • Ophthalmologists – working with infants, children and getting fast report for adults
  • Pediatricians – can screen infants and children
  • Mission trips – enables large scale screening and exams
  • ERs – checks visual response in trauma
  • Corporate Clinics – enables workforce screening
  • Schools – enables mass screenings

Measurements

  • Binocular Refraction
  • Monocular Refraction
  • Pupil Distance
  • Pupil Size
  • Head Tilt
  • Direction of Gaze
  • Phorias and Tropias
  • Lens Centering
  • Presbyopia
  • Pupil Response

Key Features

  • Extended measurement range
  • Fully automated
  • Binocular refraction
  • Pupil diameter
  • Dynamic pupilometry
  • Check of lens correction
  • Lens centering on spectacle frames
  • Fully automated and easy to use
  • Operates at 1 m (3’ 3”)
  • Fast measurement
  • Handheld and light weight
  • Battery operated
  • Allows the early detection of refractive errors
  • Ideal with infants, children and non-cooperative patients
  • No drops required
  • Connectable to IR printer
  • Customizable with additional features

Specifications

  • Operating mode: binocular/monocular
  • Refraction Measurement: Automatic
  • Sphere range: 15, -15 D, step 0.25 D
  • Cylinder range: 5, -5 D, step 0.25 D
  • Cylinder axis: 1° – 180°, step 1°
  • Pupil size: Automatic detection, 4-11 mm, step 0.1 mm
  • Pupil distance: Automatic detection, 30-120 mm, step 1 mm
  • Fixation target: Built-in
  • Acoustic target: Built-in
  • Working distance: 1 m ± 5 cm
  • Data Interface: Wi-Fi, USB, microSD card
  • Printer interface: USB, Infrared (irda)
  • Power: rechargeable battery
  • Battery charger: 110-220 Vac, 0.5 A
  • Size: 165x130x98mm
  • Display: 3.5’’
  • Weight: 840 g (30 oz)
  • Options/Accessories: supplementary battery, battery-charger, metal case, Wi-Fi connectivity

Benefits

2WIN enables you to perform refractometry by using the most innovative, versatile

and accurate technology

  • BINOCULAR, 1 METER WORKING DISTANCE

Binocular refraction measurement in natural vision conditions.

  • EASY, QUICK, NON-INVASIVE

The 2WIN takes measures fast, in natural mydriasis and in a non-invasive way

  • DYNAMIC PUPIL RESPONSE

Dynamic pupil response to programmable light stimulations.

  • WIFI AND PRINTER CONNECTED

The 2WIN connects to the internet and allows you to share, record and print exams.

  • LENS CENTERING ON FRAME

Correspondence between the optic center of the lens and the actual visual axis of the eye.

  • LONG LIFE OPERATED BATTERY

Long life batteries allow long intervals of use.

Areas of excellence

  • RAPID PATIENT VISION TESTING AND SCREENING
  • REFRACTION AND VISION ANALYSIS OF INFANTS (0-3 YEAR)
  • VISION CARE OF DISABLED AND/OR UN-COOPERATIVE PATIENTS
  • ANALYSIS OF BINOCULAR VISION AND ACCOMMODATIVE BALANCE
  • EARLY DETECTION AND DOCUMENTATION OF MULTIPLE AMBLYOGENIC FACTORS
  • OBJECTIVE ANALYSIS OF UNDER- OR OVER-CORRECTIONS
  • OBJECTIVE REFRACTION EXAMINATION

Corneal Reflexes Application [CR-App]

Thanks to the “Analysis of Corneal Reflexes”, the 2WIN can help your daily work by automating the analysis of refraction with a documented information of phorias and tropias (horizontal and vertical). This application provides complete information regarding the position of corneal reflexes. The CR-App compares the position of the corneal reflexes in three defferent mesurements (the first binocular, the second and the third monocular under an infrared occluder.)

Dynamic Pupillometry [DP-App]

Automatic measurement of dynamic pupil response to programmable light stimulations enables the detection of subtle pupillary changes, removing subjectivity from the pupillary evaluation.

Intermediate Vision Application [66cm-App]

Thanks to the 2WIN application “Intermediate Vision”, it is possible to identify the difficulties in focusing at VDUs Distance and to estimate the power of the additional lens needed on top of the prescription. The 2WIN measures the patient’s refraction while reading from VDUs, at a distance of 66 cm (2’). In all those cases when reading at such distance proves difficult, the 2WIN calculates the necessary additional power (ADD) to restore the best vision.

The application requires the use of an additional lens that is inserted in the central aperture of the 2WIN; the additional add-on lens, together with a 66 cm reading chart compose the kit.

2WINNY – KIDS MASK KIT

The 2WINNY mask is fun and attractive and can be attached to the front of the 2WIN. It is an accessory designed to draw the child’s attention to the 2WIN during the examination while activating visible and audible fixation targets. It is removable to help the operator select the appropriate mask for the child, depending on his age and design preference.