Refurbished MINDRAY WATO EX-65

Refurbished
2011
Portugal
6 457
(plus shipping costs and VAT)
Price in seller currency:
6 000
Secure Transaction via Bimedis platform
More details
Protection of Buyer's and Seller's Rights
Safe Payment
Personal multilingual support

Product Details

MINDRAY
WATO EX-65
Anesthesia Machines
14.03.2024
775

Product Specifications

Portable

Product Description

The Wato EX-65 anesthesia machine is equipped with smart ventilator technology and enhanced monitoring capabilities. The Wato EX-65 offers a full range of control and backup ventilation modes; including PCV-VG, SIMV-VG and others to fully meet the ventilation requirements of all your patients. With new anesthetic agent calculation software and an intuitive user interface, the Wato EX-65 offers more efficient support for gas consumption, anesthetic agent configuration and parameters that help reduce wasted distribution and costs inherent.

Dimensions

  • Height – 1350mm
  • Width
    • Without breathing circuit – 700mm
    • With breathing circuit – 950mm
  • Depth – 610mm
  • Weight – 120kg (sem vaporizadores e cilindro)

Top Shelf

  • Weight limit: 30 kg
  • Width: 480mm
  • Depth: 440 mm

Retractable work surface

  • Height: 860 mm
  • Area: 1012 cm2

LED Light

  • Illuminates all work surface

Drawers – locking internal dimensions

  • Height: 170 mm
  • Width: 350 mm
  • Depth: 270 mm

Casters

  • Diameter: 125 mm
  • Brakes: Individual locking

Ventilator Performance

  • Pressure range at inlet: 0.28~0.6MPa
  • Peak gas flow: 100L/min plus fresh gas
  • Flow value range: 1 to 100 L/min

Ventilator Parameter Ranges

  • Tide Volume Range: 40~1500ml (VCV mode)
  • Incremental settings:20~100ml (increments of 5 ml) - 100~300ml (increments of 10ml) - 300~1500ml (increments of 25ml)
  • Pressure (inspired) range: 5~60 cmH2) - increments of 1 cmH2O
  • Rate Range: 4~100bpm increments of 1 bpm (VCV, P-mode) - 4~60bpm increments of 1bpm (SIMV)
  • Inspiratory/Expiratory ratio (I:E) range: 4:1~1:8 increments of 0.5 (VCV, Pmode)
  • Inspiratory pause time: OFF, 5~60% of inspiratory time increment of 5%
  • Trigger window: 5-90% increments of 5% (SIMV)
  • Flow Trigger: 0.5~15L/min increments of 0.5L/min (SIMV)
  • Pressure trigger: -20~ -1cmH2 O increments of 5% (SIMV)