Used Very Good DRAGER Fabius GS

Used Very Good
1
In stock
France
3 054
(plus shipping costs and VAT)
Price in seller currency:
2 850

Seller:

Product Details

DRAGER
Fabius GS
Anesthesia Machines
03.04.2024
432

Product Description

DRAGER Fabius GS

ANESTHESIA MACHINE

Good condition

USED, Powers Up (not tested in real conditions)

With the O2 sensor and reusable canister / absorber

FEATURES:

The Drager Fabius GS is an inhalation anesthesia machine used in an operating, induction, and recovery rooms. It can be used with O2, N2O, and AIR supplied by a medical gas pipeline system or have externally mounted gas cylinders. The Fabius GS is equipped with a compact breathing system that provides fresh gas decoupling, PEEP, and pressure limitation. This anesthesia machine has 5 main ventilation options that include; Volume Controlled Ventilation, Pressure Controlled Ventilation, Pressure Support, Manual Ventilation, and Spontaneous Breathing. Its equipped with an electrically driven and electronically controlled ventilator that monitors for airway pressure (P), volume (V), and inspiratory oxygen concentration (FiO2).

The Drager Fabius GS anesthesia machine is a popular choice for practitioners who demand advanced ventilation technology combined with reliable and proven breathing system components. The Fabius GS anesthesia workstation opens new frontiers in ventilation performance while maintaining well-established functionality.

High-performance ventilation with versatility that’s more flexible and economical to use than traditional gas-driven bellows ventilators

Full-color screen

Compact, convenient breathing system thats ergonomically designed for optimal positioning

ClinicalVision – monitoring solution that allows the caregiver to view patient monitoring and clinical data simultaneously

Customized design for flexibility and ease of use

Ready for IT-integration

Low-flow ventilation

Electronic vertical flow controls and electronic fresh gas flow indicators

Intelligent cable management for reduced clutter and easier patient trans

Easy integration into existing hospital information system

Central braking

Continuous monitoring during transport and automatic reconfiguration of site-specific parameters with Dräger’s innovative Infinity Docking Stations (IDS).

Drager Fabius GS Specifications

Rechargeable Batteries

Raitng: 24V; 3.5 Ah

Type: Sealed, gelled lead-acid

Recharge Time: ≤ 16 hours on the mains or full operation time

Operating time with fully charged batteries: 45 minutes, minimum

Ventilator Input Ranges

PMAX Pressure Limiting: 15 - 70 cmH2O (1 cmH2O resolution)

VT Tidal Volume: 20 - 1400 mL (10 mL resolution)

VT (SIMV/PS) Tidal Volume: 20 - 1100 mL (10 mL resoltuion)

f Breathing Frequency: 4 - 60 bpm (1 bpm resolution)

Ti/Te Inspiration/Expiration ration: 4:1 to 1:4

Tip/Ti Inspiration pause: 0% - 50% (1% resolution)

PEEP End-expiratory Pressure: 0 - 20 cmH2O (1 cmH2O resolution)

Pinsp Inspiratory Pressure: 5 - 65 cmH2O (1 cmH2O resolution)

Insp Flow Inspiratory Flow: 10 - 75 L/min (1 L/min resolution in Pressure Control Mode; 10 - 85 L/min (1 L/min resoltuion) in PS and SIMV/PS modes

Δ PPS (Pressure Support) Support Pressure: 3 - 20 cmH2O (1 cmH2O resolution)

Δ PPS (SIMV/PS) Support Pressur : 3 - 20 cmH2O, OFF (1 cmH2O resolution)

Freq Min Apnea Ventialtion minimum frequency: 2 - 20 bpm (1 bpm resolution) and OFF

Trigger: Trigger Level: 2 - 15 L/min (1 L/min resolution)

Tinsp SIMV Inspiratory Time: 0.3 - 4.0 sec

Pressure Support Ventilation Mode

Endotracheal Tube Size: 4.5 mm - 8 mm

Patient Lung Compliance: 10 ml/cmH2O - 100 ml/chH2O

Unassisted Patient Tidal Volume: 50 ml - 1000 ml

Patient Breath Rate (BPM): 10 - 35

Delivery Accuracy

Pmax Pressure Limiting: ±5 cmH2O of setting

VT Tidal Volume: ± 5% of setting or 20 mL, whichever is greater

f Breathing Frequency: ±1 bpm of setting

Ti/Te Inspiration/Expiration Ratio: ±5% of setting

Tip/Ti Inspiration Pause: ±25% of setting

PEEP End-expiratory Pressure: ±2 cmH2O or ±20% of setting, whichever is greater

Safety Reliefs

High Pressure Safety Relief Valve: 75 ±5 cmH2O

Negative Pressure Safety Relief Valve (Ambient Air Inlet Valve): -7.5 to -9 cmH2O

System Compliance Compenstation Measurement: 0.2 to .0 ml/cmH2O: ±0.2 ml/cmH2O or ±10% of actual complaince, whichever is greater

Anesthesia Gas Supply Module

Fresh Gas Flow Indicators: O2, N2O, Air: Range and accuracy: 0.0 to 12.0 L/min ±10% of reading or 0.12 L/min (into an ambient atmosphere of 14.7 psi (101.3 kPa) at 20°C). Resolution: 0.1 L/min

Fresh Gas Flow Stability: O2 and N2O: ±10% of setting with pipeline pressures between 45 - 65 psi; Air ±10% of setting with pipeline pressures between 50 - 55 psi; Air flow rate will vary proportionally with supply pressures outside 50 - 55 psi

Total Fresh Gas Flowmeter: Range and accuracy: 0 to 10 L/min ±10% of full scale at STP, calibrated with 50% O2 / 50% N2O gas mixture; 0 to 10 L/min ±15% of full scale at STOP for all other gas mixtures; Resoltuion: 0.5 L/min from 0.5 - 2 L/min; 1.0 L/min from 2 - 10 L/min

O2 Flush (bypass): at 55 psi (3.8 bar) max. 50 L/min; at 50 psi (3.4 bar) min. 35 L/min

Common Gas Outlet Pressure Limit: 13 psi (0.9 bar)

International Shipping

We do our best to ship items the same day the payment has cleared, in some instances we are unable to. All items will be shipped within 1-4 working days

Returns

If you are not 100% satisfied with your purchase, we have a 14-day money back guarantee policy. Excluding Items sold as-is / for parts only. Reimbursement for returns will be paid after the purchased item is returned. Free returns apply to damaged, broken and items not as described! Buyer is responsible for return shipping on items purchased accidentally or items no longer wanted/needed etc.

We ship worldwide !

Please feel free to contact us for any question!

We ship worldwide !