CARL ZEISS IOL MASTER 500 optical biometer

Used Very Good
3
In stock
Poland

Seller:

Poland

Product Details

ZEISS
IOL Master 500
A-Scan
17.05.2023
295

Product Specifications

1.5 – 6.5
5-10
Haigis, Hoffer Q, Holladay 1 and 2, SRK II, SRK / T
50/60
1
100-240
Show

Product Description


Reconditioned (used),
Technical condition: very good,
Visual condition: very good,
Real photos of the product,
Made in Germany,
Power supply: 230 V,
Frequency: 50/60 Hz,
Power: 75 VA,
IOL Master 500 from ZEISS is the gold standard in optical biometry, with more than 100 million successful IOL lens power calculations so far. It is an excellent choice for cataract surgeons looking for a reliable, fast and easy-to-use optical biometer for measurements they can rely on,
Main characteristics:

High-speed Biometrics. Minimize acquisition and chair time by taking fast accurate measurements. In Dual mode, axial length and keratometry are recorded in a single measurement. Switching between modes is fully automatic and requires no user interaction. The average time required to take a read-out on the IOL Master 500 is up to 4 times shorter compared to other optical devices,
Excellent cataract penetration. The IOL Master 500 achieves a measurement success rate that is up to 20 percent higher than other optical biometric devices. Basic composite signal evaluation not only significantly increases the percentage of cataracts measurable with optical technology, but also significantly increases the signal-to-noise ratio - a measure of the exceptional reliability of the data provided by the IOL Master 500,
Ease of use. A well-designed user interface, reliability controls, distance-independent measurements, and up to 4 times faster read-out compared to other optical devices provide exceptional usability and reduced work time. A difference that you, your team and your patients will notice every day,
Proven Toric Results. The results of a meta-analysis of 28 published clinical articles, covering more than 1,900 cases, show that the reported clinical results for ZEISS IOL Master lenses for residual astigmatism exceed or are at least as good as those obtained with manual or automatic keratometry,
Advanced measurement of challenging eyes. The true test of a biometer is its performance with challenging eyes. In denser cataracts, the ZEISS IOL Master 500 achieves a measurement success rate up to 20% higher than other optical biometry devices. Even in staphyloma, pseudophakic eyes and silicone-filled eyes, the ZEISS IOL Master 500 measures along the visual axis, achieving the correct axial distance. With the Haigis-L formula, the ZEISS IOL Master 500 lens is designed for myopic and hyperopic cases after LVC,
Marker-free alignment of toric IOL lenses. The option reference image is the starting point for the workflow of the markerless toric IOL lens. An image of the eye is taken along with a keratometric measurement.  Both, the reference images and the keratometric data are transferred to the computer-assisted surgical system ZEISS CALLISTO eye. Finally, all data needed for precise alignment and marker-free toric IOL lenses are entered into the eyepiece of the ZEISS surgical microscope,
Optimize refractive results. Each intraocular lens calculation is only as reliable as the lens constant on which it is based. More than 40,000 patients’ data sets created with ZEISS IOL Master form the basis of more than 200 optimized lens constants on the User Group for Laser Interference Biometry (ULIB) website - absolutely unique in the industry. Together with its unique distance-independent telecentric keratometry and unique integrated Holladay 2 formula, the gold standard in optical biometry helps to optimize refractive outcomes,


Specification:

Measurment range:

Axial length 14 - 38 mm,
Corneal radius 5 - 10 mm,
Anterior chamber depth 1.5 - 6.5 mm,
White-white 8 -16 mm,


IOL calculation formulas:

SRK II, SRK/T, Holladay 1 and 2, Hoffer Q, Haigis,
The clinical history and contact lens fitting method for calculating corneal refractive power after corneal refractive surgery,
Haigis-L IOL calculation for eyes after LASIK / PRK / LASIK myopia / hyperopia surgery,
Calculation of phakic anterior and posterior chamber implants,
Fixed IOLs optimization,


Display scaling::

Axial length 0.01 mm,
Corneal radius 0.01 mm,
Anterior chamber depth 0.01 mm,
White-white 0.1 mm,




Software version: 7.7.4.0326,
Menu to be chosen in the following languages: EN, DE, FR, ES, IT, SE, DK, JP, CN, KR, CZ, RU,
Mobile, on a table equipped with 4 wheels with a brake and electric height regulation of the top in the range of 72-97 cm,
In the set:

Polish instruction manual,
Trial eye,
Keyboard,
Original case,
Power cord,


Dimensions:

Overall: 60 x 47 x 133-158 cm,
Of the table: 60 x 44 x 72-97 cm,


Weight: 43 kg,
Provided with a valid Technical Passport,
Guarantee:

6 months for the domestic market (Poland),
3 months for the international market,


Financing possibilities (Poland only): Installments, leasing, loan,