CARL ZEISS 2014 ZEISS IOL MASTER 500 Version 7.7 and Holladay 2 Software. A-Scan

Refurbished
1
2014
In stock
USA
Secure Transaction via Bimedis platform
More details
Protection of Buyer's and Seller's Rights
Safe Payment
Personal multilingual support

Product Details

ZEISS
IOL Master 500
A-Scan
14.12.2023
393

Product Specifications

1.5 – 6.5
5-10
Haigis, Hoffer Q, Holladay 1 and 2, SRK II, SRK / T
50/60
1
100-240

Product Description

2014 ZEISS IOL MASTER 500 Version 7.7 with Holladay 2 Software.

IOL MASTER SW OPTION SONOLINK 2013
IOL MASTER SW OPTION N
IOL MASTER SW OPTION T
IOL MASTER SW OPTION HOLLADAY 2

4 20013 IOL MASTER AVAILABLE.


Condition: Refurbished.

6 MONTHS WARRANTY ONLY IN US.

This instrument is in excellent condition and has been fully refurbished by our staff.

ALL THE EQUIPMENT WE OFFER IS BECAUSE WE HAVE THEM IN STOCK.

Shipping is only to the lower 48 states, international buyers are welcome as long as you are willing to pay the cost of international shipping, just contact me before bidding.
Paypal payment is preferred, but wire transfers, Check and money orders are also accepted.

Fully Refurbished

INCLUDED :
- PDF Manual
- Keyboard
- Guide Manual
- Power Table.
- Printer.
- Zeiss IOL eye test

Transfer of IOLMaster patient measurements to the Holladay IOL Consultant
Professional Edition program (HIC – PRO)
The IOLMaster® performs biometric measurements for the purpose of intraocular lens power calculation in preparation for
cataract surgery. It also provides on-board lens power calculation capability as well as patient data management and lens
constant personalization (also called optimization.)
The Holladay IOL Consultant Professional Edition (HIC – PRO) is a third-party software program developed, distributed, and
supported by Jack Holladay MD that runs on a separate computer and provides intraocular lens power calculation, lens constant
personalization, and surgical outcomes analysis. It also contains a proprietary lens power calculation formula called the Holladay
2 formula, which is not available on the IOLMaster. The HIC – PRO program cannot be loaded or run directly on the IOLMaster
instrument at this time.
IOLMaster users wishing to use the HIC – PRO program for IOL power calculation must transfer IOLMaster patient measurement
data into the HIC – PRO program. This document identifies several methods for this data transfer and provides setup and data
transfer guidelines. These methods were developed from a collaborative effort between Carl Zeiss Meditec and Jack Holladay
MD for the benefit of our mutual customers.
Disclaimer: Please Read
Carl Zeiss Meditec, Inc. (CZM) is not responsible for the results provided by the HIC-PRO Program. The HIC-PRO is a third-party application; users are advised to contact Jack Holladay MD at (support@hicsoap.com) for technical and clinical support.
This document does not represent or imply any commitment for sales, installation and setup, technical or clinical support of the
HIC-PRO program. Our tech support team has very limited knowledge of the HIC-PRO program’s operation. CZM does not
provide sales, installation, setup, configuration, training, or troubleshooting support for a customer’s network. This document
provides guidance to assist an IT professional when configuring the Holladay IOL Consultant Professional Edition to access
patient data from an IOLMaster 500 via Ethernet. CZM may provide guidance on a best-effort basis but is not responsible for the
setup and administration of a user’s office network

• All-in-one biometer: axial length and keratometry measurements as well as IOL power calculation in one device
• Dual Mode: axial length and keratometry measurements without unnecessary manual interaction
• Easy patient adjustments: distance independence of axial length and keratometry
• Composite Signal: for best-in-class cataract penetration
• Flexible platform: automatic or manual mode for customized treatments
• Robust platform: fully integrated system components, including formulas
• One consistent graphical user interface: for all formulas, including Holladay 2
• Most comprehensive set of formulas: includes fourth generation Haigis and Holladay 2
• Holladay 2 onboard: incorporated into the IOLMaster 500 formula selection; no need to export data, reducing transcription errors
• Haigis-L formula: for post-LVC patients
• Measurements along visual axis: for relevant axial distance, even in eyes with staphyloma
• Measures challenging eyes: pseudophakic and siliconefilled eyes as well as eyes with phakic IOL
• More comprehensive IOL calculation: for virtually all common IOL types
• Phakic IOL calculation: both anterior and posterior
• ULIB database: contains continuously optimized IOL lens constants to improve refractive outcomes
• Convenience: Sonolink for integrating Accutome A-Scan synergy ultrasound device
• Data integration: into FORUM data management system
• DICOM interface: for integration into EMR systems

Technical Data:

Measurement range Axial length 14 - 38 mm
Corneal radii 5 - 10 mm
Anterior chamber depth 1.5 - 6.5 mm
White-to-white 8 -16 mm
Display scaling Axial length 0.01 mm
Corneal radii 0.01 mm
Anterior chamber depth 0.01 mm
White-to-white 0.1 mm

IOL calculation formulas
SRK® II, SRK® / T, Holladay 1 and 2, Hoffer Q, Haigis
Clinical history and contact lens fitting method for calculation of corneal refractive power following refractive corneal surgery
Haigis-L IOL calculation for eyes following
myopic / hyperopic LASIK / PRK / LASEK surgery
Calculation of phakic anterior and posterior chamber implants
Optimization of IOL constants
Interfaces Ultrasound data link (to Accutome A-Scan synergy)
ZEISS data archive and review solution FORUM
ZEISS OR management system CALLISTO eye
Data interface for electronic medical record (EMR) / patient management systems (PMS)
Data export to USB storage media
Export database for Holladay IOL Consultant and HIC.SOAP Pro
Ethernet port for network connection and network printer
Line voltage 100 - 240 V ± 10 % (self sensing)
Line frequency 50 - 60 Hz
Performance consumption: max. 75 VA
Laser class 1


Warranty information can be found within the product description. Warranties will vary by product, condition (Factory New, Factory Refurbished, and Certified Refurbished), and by the manufacturer.

Factory New Items: Warrantied by and through the manufacturer. All warranty claims must be processed through the original manufacturer. A.O.E is available to assist with any manufacturer warranty claims.
Factory Refurbished: Products are warrantied by and through the manufacturer. All warranty claims must be processed through the original manufacturer. A.O.E is available to assist with any manufacturer warranty claims.
Certified Refurbished: Include a warranty through A.O.E. The warranty on certified items is a parts & labor warranty that covers faulty components and defects. Warranty does not cover routine maintenance, consumables, everyday wear items, and user damage. After the expiration of the warranty period, A.O.E is available to assist with technical support.


* Please note that shipping charges are usually not covered under warranty for non-continental US orders and orders for Factory New and Factory Refurbished items.


Submit a Warranty Claim

To submit a warranty claim, please contact us with details on how (steps executed) and when (time and date) the problem occurred. We will also require the order number, serial number, and media (photos & videos showing the issue and how everything is connected).

Our team will open a support ticket and assist you every step of the way.

Certified Satisfaction Guarantee

A.O.E has certified technicians who are standing by to assist with any questions. Although issues are rare, they can appear and usually are easily resolved over the phone. If the problems are not resolved remotely, our team will determine whether the item should be sent back to A.O.E or send a technician on-site for repairs.

To expedite a response to your issue, be prepared to provide details on how (steps executed) and when (time and date) the problem occurred. We will also require the order number, serial number, and media (photos & videos showing the issue and how everything is connected). Let us know if you feel that our quality does not meet your expectations, and we will work to achieve your satisfaction.

Extended Warranties

Extended warranties are available for purchase up until the date of standard warranty expiration. Please keep in mind that any item(s) out of warranty or not purchased through A.O.E will either need to be sent in for calibration or certified on-site by an A.O.E -hired technician prior to purchase (charges may apply).

Product Service (Out of Warranty)

Our technicians & engineers offer services for items that are out of warranty or not purchased through A.O.E Medical. These services include repair as well as certification. Most services are billed at an hourly rate, and we do offer some flat rate repair or exchange services for specific items.
Return Policy